Home

ADVANCE Medial Pivot Knee surgical technique

18. Smith & Nephew Surgical Technique for Profix® TKA. 19. Stryker Surgical Technique for Scorpio® TKA. 20. Wright Medical Technology Surgical Technique for ADVANCE® Medial-Pivot TKA. 21. MK282-1000 22. Biomet Surgical Technique for Ascent™ TKA. 23. Johnson & Johnson, DePuy Surgical Technique for PFC® Sigma Rotating Platform TKA. 24 ADVANCE® Stemmed Medial Pivot Knee ADVANCE® Post Stabilized Knee PFC® Sigma Knee Duracon® Knee Nexgen® Knee VOLUME OF BONE REMOVED20 The ADVANCEfi Stemmed Medial-Pivot femoral components offer all the surgical options of a traditional revision femoral component such as augments, stem extensions and stability. However, Tapered cemented. The Evolution® Medial-Pivot knee system is built upon a legacy of 95% patient satisfaction with 98.8% survivorship at 17 years 1, and features a design that enhances quadriceps efficiency, allowing for improved proprioception and more normal feeling knee. 5. Learn more about the Evolution® medial-pivot knee outcomes

The ADVANCE Medial-Pivot Knee (AMP) System (MicroPort Orthopedics Inc., Arlington, TN, USA) is one of the older implants (second-generation TKA) designed to replicate normal tibiofemoral joint kinematics The eMP™ Medial Pivot Knee System aims to answer these traditional implant limitations, by providing an implant that delivers flexion stability, anatomic motion and wear limiting design. MicroPort's Medial Pivot design has been tested and proven to be patient preferred over other knee replacements.4 20 years of stabilit Today, according to the latest literature, nearly 20% of all patients are unhappy with their total knee replacement due to residual pain, functional issues a.. The ADVANCE® Medial Pivot (AMP) Knee System was designed with a highly congruent medial compartment and a less conforming lateral compartment to more closely mimic the kinematics of the normal knee and to offer more stability through out of range of motion (ROM) Objective: kinematic alignment technique has been recently described as a new surgical procedure able to restore the patient specific physiological knee alignment; furthermore, new prosthesis, as medial stabilized (MS) third generation TKA, were designed to better reproduce the anatomical shape of the knee

Advance Knee System - spot

  1. The medial pivot implant design was developed to more closely mimic native knee motion, in the hope of improving function, and not primarily as a more constrained knee for difficult cases. In the past 10 to 12 years, a second-generation medial-pivot design has emerged, but there are no larger registry studies on the survival of these implants
  2. The eMP™ Knee System addresses the limitations of traditional designs and today's patient needs by delivering superior flexion stability, anatomic motion, and wear-limiting design characteristics through three primary knee options. The three options offered are: Cruciate-Substituting (CS), Cruciate-Retaining (CR), and Posterior Stabilized (PS)
  3. ADVANCE® Medial Pivot (MP) (Wright Medical) total knee arthroplasty (TKA) was established to replicate normal tibio-femoral knee joint kinematics, however, its influence on the patello-femoral (PF) joint is unclear. The purpose in this study was to assess the PF joint conditions in Advance MP TKA, via radiography and three-dimensional image-matching software

MicroPort ® Orthopedics has announced a '15A' rating from the Orthopedic Data Evaluation Panel (ODEP) for its independently-developed Advance ® Medial-Pivot Knee System.. Established in the United Kingdom in 2002, ODEP is a global rating agency within the orthopedic industry that provides a standardized, validation rating system based on survivorship and the quality of implants. Within this surgical technique two instrument kits are described. The K100KT70 kit has to be used for implantation of the cemented ADVANCE® tibial components, with the option of implanting a cementless or cemented keel. The K100KT74 kit has to be used for implantation of the BIOFOAM® (cementless) ADVANCE® tibial components Deep Flexion: The articulation of the EMPOWR 3D Knee is less conforming in deep flexion, allowing the soft tissues to drive femoral rollback and natural medial pivot motion. The widened medial condyle encourages external rotation, similar to the natural knee, and aids in patellar tracking and quadriceps function during deep flexion. ADVANCE is characterized mainly by incorporation of a ball-in-socket mechanism into the medial condyle and an arch-like groove with semiconformity of the outside, allowing anterior and posterior movement. Based on the concept of these designs, ADVANCE is aimed at reproducing medial pivot motion and normal knee movements Nine ADVANCE (Wright Medical Technology, Arlington, TN)) Medial-Pivot (MP) and 9 ADVANCE Double-High total knee arthroplasties were analyzed under radiographic surveillance at standing, mid kneeling, and full kneeling. In vivo tibiofemoral contact positions were obtained using the 3- to 2-dimensional image registration technique

Total Knee Arthroplasty with WrightMed's ADVANCE Medial Pivot Prosthesis (a first in Cebu) she has a long antero-medial incision scar on her right knee -- and that she spent 3 months in a long leg plaster cast after that; no re-operations, no recall of any implants ever being used.) so no hitches for me with the surgery itself. For the. The adoption of this advanced surgical technique allows our medial-pivot surgeons to combine the benefits of medial-pivot kinematics and stability with a kinematic approach designed to individualize knee implantation to best suit each patient, said Benny Hagag, President long medial pivot heritage. In 1985, the Natural-Knee ® System was launched with a UC bearing and introduced the concept of constraint through conformity. In 1986, the M/G ® I CR Femur was released with asymmetric femoral condyles designed to simulate the medial pivot motion of a healthy knee. The NexGen ® Knee Purpose The ADVANCE® Medial Pivot Knee System was designed with a highly congruent medial compartment and a less conforming lateral compartment to more closely mimic the kinematics of the normal knee. The purpose of this study was to evaluate the midterm clinical and radiographic outcomes of this total knee arthroplasty (TKA) system. Methods Between January 1998 and December 2006, 421 primary.

Evolution® Medial-Pivot Knee Advantage MicroPort Orthopedic

  1. Fig. 1 (A) Photograph of the medial pivot knee showing a deeper and more medial surface of the articular insert that articulates with a congruent medial femoral condyle and the anterior lip that provides stability in flexion and a less congruent lateral surface that allows free movement of lateral femoral condyle along an arcuate path
  2. The ADVANCE® Stemmed Medial-Pivot Knee offers the same kinematic benefits as the primary ADVANCE® Medial-Pivot Knee, yet accepts a full line of augments, stems, and tibial bases. Unlike other revision systems, the ADVANCE® Stemmed Medial-Pivot Knee signifi cantly reduces femoral bone loss by not requiring a full housing resection
  3. The Advance Medial Pivot Total Knee Arthroplasty (Wright Medical Technology, Arlington, Tennessee, USA) has been designed to reproduce modern ideas of knee kinematics. We report a prospective clinical outcome study of 284 arthroplasties in 225 consecutive patients with a mean follow-up of 6.7 years (range 4 to 9 years)
  4. Total knee replacement (TKR) is commonly done orthopaedic procedure to treat knee pain and improve functional activities of patients suffering from osteoarthritis. The ideal TKR implant should substitute the normal kinematic of the human knee. The ADVANCE®Medial Pivot Knee System (AMP) is designed as suc

years after TKA using an ADVANCE Medial Pivot Knee in weight-bearing motion. Methods: Seventy-six knees (76 patients, 15 male and 61 female) that underwent TKA with the ADVANCE Medial Pivot Knee prosthesis were assessed in this study. The patients who underwent TKA at least 5 years after surgery were chosen for this study Youm YS, Cho SD, Lee SH, et al. Total knee arthroplasty using a posterior cruciate ligament sacrificing medial pivot knee: minimum 5-year follow-up results. Knee Surg Relat Res 2014;26:135-40. Karachalios T, Roidis N, Giotikas D, et al. A mid-term clinical outcome study of the Advance Medial Pivot knee arthroplasty. Knee 2009;16:484-8

A mid-term clinical outcome study of the Advance Medial

Total Knee Arthroplasty with WrightMed's ADVANCE Medial Pivot Prosthesis (a first in Cebu) she has a long antero-medial incision scar on her right knee -- and that she spent 3 months in a long leg plaster cast after that; no re-operations, no recall of any implants ever being used.) so no hitches for me with the surgery itself. For the. Comparison of Patient Satisfaction Between Medial Pivot Prostheses and Posterior-Stabilized Prostheses in Total Knee Arthroplasty to surgical technique, rehabilitation training, and design of prostheses3,8. Among these factors, the design of the prosthesis the Advance (Microport, Arlington, TN, USA), the NexGe Results impacted by technique. The Advance Medial Pivot (MP) Knee resulted from licensing of the ball-and-socket concept from Finsbury in the 1990s and did not specify complete removal of the PCL. Literature reviews finding an inconsistent outcome for the concept are dominated by studies using this design, some with and some without PCL.

Advance Medial Pivot Total Knee Replacement - Pacific Surgica

The medial pivot (MP) design was invented to avoid this movement using its special asymmetric polyethylene insert, which has a highly congruent medial compartment and a less conforming lateral compartment. This design allows rolling of the medial femoral condyle, but there is no limitation to the lateral condyle 15 The natural motion of the human knee when it is functioning normally is a medial pivot pattern, and fluoroscopic studies have shown that CR and PS knees do not have a medial pivot pattern once. AP Stability with Evolution Medial-Pivot: Surgical Video. By MicroPort Orthopedics FEATURING Michael Anderson. May 31, 2017 1 Comment Addressing Varus and Valgus Deformity using the Medial-Pivot Knee Feat. D. Backstein 19:11 Step by Step Surgical Technique 10:55. Leo Whiteside. Landmarks and Ligaments in TKA 20:51

Through this webcast, Wright will provide surgeon and patient participants a complete overview of the ADVANCE® Medial-Pivot Knee System, which more closely replicates the natural kinematics of a normal knee, as well as the benefits offered through Wright's ODYSSEY™ minimally invasive surgical approach Device: Advance Medial Pivot Knee Arthroplasty medial pivot total knee arthroplasty tibial component vs standard posterior stabilized tibial component with post. Medial pivot provides a constrained medial condyle through shape of polyethylene and reduces amount of bone removal on femoral side that would otherwise be removed to accommodate PS pos

Revision Knee System Built on a 20 year, clinically-established heritage of patient satisfaction and survivorship. It is the only revision knee system that maintains the proven kinematic benefits of a medial-pivot design, while also offering surgeons intraoperative flexibility to meet all patient needs. High medial conformity and a constan Medial-Pivot implant is designed to replicate this function [2]. METHODS Radiostereometric analysis (RSA) is an accurate radiographic technique for measuring relative motion between an implant and bone [3]. Tantalum beads inserted in the tibia and implant polyethylene component during surgery are highly visible i Osso VR Announces Partnership with MicroPort Orthopedics, Launching a VR Training Module for New Hip and Knee System Innovative Virtual Reality Training Module for MicroPort Orthopedics' SuperPath® Hip Technique and Evolution® Medial-Pivot Knee System PALO ALTO, Calif., Aug. 4, 2020 - Osso VR, a validated Virtual Reality (VR) surgical training platform, today announced the launch of a VR. The fracture of the femoral component is a rare complication of a total knee arthroplasty (TKA). This article presents a case in which a 70-year-old man underwent a left press-fit Advance Medial-Pivot Knee System TKA (MicroPort Orthopedics, Arlington, TN) in 2000. Twenty years later, he experienced a nontraumatic onset of knee pain after standing up from a lunge position Medacta offers an anatomic and compartment specific, fixed bearing Medial Partial Knee. MOTO is designed to replicate every individual's anatomy in order to achieve optimal coverage, fit, balance and alignment in all patient populations in the most effective and efficient way possible. Through implant design and intense focus on.

Evolution® Medial-Pivot Knee System - YouTub

Kinematic Guided Motion providing a natural range of motion 2 with medial pivot, lateral roll back, and screw home. 3; References. 1. Hubbard K,: Condylar Load Measurement of the LEGION Hinge Knee System. Smith & Nephew Inc. Orthopaedic Research Report, OR-09-30, April 2009. 2. Johal, P, et. al. Tibio-femoral movement in the living knee Evolution™ was built on over 16 years of excellent clinical history of the first-generation medial pivot knee of MicroPort ® - Advance ® Medial-Pivot Knee System, and it offers more prosthesis systems. With extensive product line, MicroPort ® OrthoRecon successfully taps the high-end knee replacement market. Up to date, Evolution™ has been used in many countries and regions, and gained. EVOLUTION ® was built on around 20 years of excellent clinical history of the first-generation ADVANCE ® Medial-Pivot Knee System (ADVANCE ® ), with more prosthesis systems to choose from, which offers ideal solutions to patients with orthopedic diseases. EVOLUTION ® was officially launched in the China market in 2015 and has been carried out clinical applications in several domestic. Recent studies of normal knee kinematics suggest that the medial pivot theory is a better model than the J-curve for understanding knee motion . Instead of rolling back, the medial condyle spins in place like a ball-and-socket joint during flexion; the lateral femoral condyle pivots on the medial condyle as it rolls, spins, and translates [ 14. Objective: To assess whether there the final range of motion (ROM) results achieved by patients undergoing total knee arthroplasty (TKA) with prosthesis using Medial Pivot design are predictable. Methods: Between January and August of 2014, 155 patients with primary osteoarthritis of knee who underwent TKA using the prosthesis ADVANCE® Medial Pivot were prospectively assessed

Medial Pivot in Total Knee Arthroplasty: Literature Review

Medial-Pivot Knee System ⋆ Joint Academy Micropor

The Advance medial pivot knee (Wright Medical Technology) was created in an effort to prevent stiffness postoperatively and increase range of motion. The Evolution medial pivot knee is a second-generation design that builds on the technology of the Advance knee. This article describes the demographics, diagnosis, surgical technique, and. Robotic systems can efficiently carry out complicated tasks that require a high degree of accuracy and precision. This has resulted in robotics being used in a variety of neurosurgical applications such as intracranial biopsies, spinal instrumentation, and placement of intracranial leads Regardless of the surgical procedure used to reconstruct both PCL and PLC, good and excellent clinical outcomes were reported in 32% and 52% patients, respectively. However, surgery did not restore normal laxity of the affected knee, especially regarding range of motion, posterior drawer and rotational laxity

Mitra Fajar Selaras is one of the leading healthcare product distributor companies in Indonesia. We are focused in marketing of Spine Products, Trauma Products, Joint Products, Bone Graft, CMF, Laser, Power Tools, Orthopaedics, Neurosurgery, Surgical Instruments for all specialties, and other Advanced Surgical products and Technologies Hip and knee replacement arthroplasty are profoundly successful operative interventions, however, some joint replacements do fail and the life expectancy of a hip or knee arthroplasty is finite. This fact has largely been responsible for the continued development of new devices and techniques for joint arthroplasty surgery The mean follow-up period was 21.7 ± 4.5 months. No kinematic differences were found between the SB and SBLP groups (P > .05).A more medial tibial position (P < .05) of the ACL-injured group was reported during the entire motor task and persisted after ACLR in both the SB and the SBLP groups.Differences in IE and varus-valgus rotations were found between the ACL-injured and healthy groups knee (ADVANCE® Medial-Pivot Knee System, Wright Medical Technology, Inc., Memphis, TN) from March 2002 to December 2003. All of the cases were females and their average age was 66.8 (54 to 77) at the time of surgery. As for the surgical location of the body, 18 cases had surgery on their right side and 22 cases had it o

To compare the clinical outcome of posterior cruciate ligament (PCL) retention type and PCL substituting type using Advance(®) Medial Pivot (AMP) inner-axis knee prosthesis. A retrospective analysis was conducted on the cases of total knee arthroplasty (TKA) with AMP prosthesis in the Affiliated Hospital of Qingdao University from January 2011. advance Osteoarthritis, the most common procedure is total knee replacement surgeries and the number of TKR surgeries is expected to increase by more than 600% by 20302. In USA, TKR is the most common orthopaedic surgery to be performed in the recent years for the management of severe osteoarthritis of the knee joint4. Total knee arthroplasty.

Evolution® Medial-Pivot Knee System Animation - YouTub

A long term clinical outcome of the Medial Pivot Knee

After the surgery, the day continued with several talks from the invited national experts in knee. On one hand, Dr. Amillo gave a lecture explaining the Concept of Medial Pivot Kinematics in knee designs and a second one regarding Indications and limits of Advance Medial Pivot From March 2002 to Dec 2003, 40 total knee arthroplasties with a cruciate retaining medial pivot knee were implanted in 28 cases. The average follow-up period was 2.8 years (range, 2 to 3.7 years). The clinical and radiographic results were evaluated using the clinical and roentgenographic evaluation and scoring system of the American Knee Society EMPOWR 3D Knee®. The EMPOWR 3D Knee addresses natural motion throughout a full range of motion, from early to deep flexion, creating a more natural feeling knee for the patient. DJO Surgical. EMPOWR Partial Knee™. The EMPOWR Partial Knee™ is the efficiency-based solution for early stage, unicompartmental knee arthritis in today's modern. When replacing the human knee, we attempt to reproduce the stability of the normal knee so that the patient perceives the knee arthroplasty to feel and function similar to a normal knee. Avoiding instability requires understanding the definition and implication of stability to the implant design features and the arthroplasty procedure. The purpose of this paper is to define the elements of.

Combining kinematic alignment and medial stabilized design

The MicroPort orthopedics Advance® medial-pivot knee system was launched in 1998, making it the first medial-pivot knee system available on the market. A culmination of years of research and design by Wright Medical and Dr. J. David Blaha resulted in a truly unique knee replacement design. With over 20 years of documented usage, MicroPort. 4. A mid-term clinical outcome study of the Advance Medial Pivot knee arthroplasty. Karachalios T, Roidis N, Giotikas D, Bargiotas K, Varitimidis S, Malizos KN. Knee. 2009 Dec;16(6):484-8. 5. Total knee replacement performed with either a mini-midvastus or a standard approach: A prospective randomized clinical and radiological trial In this study, MP (Advance Medial-Pivot Knee System, Wright Medical Group) or PS prosthesis (NexGen LPS-Flex, Zimmer, Warsaw, IN) were adopted. Patients were placed into the supine position, with general anesthesia and a nerve block being used before surgery, and electric pneumatic hemostat as well as 300 mmHg pressure was used at the start of. MCL and medial-sided knee injuries are still major problems in the modern era of sports medicine. With advances in imaging techniques and refined grading of injuries, surgical treatment for medial-sided knee injuries, once popularized by Hughston, may have a role in many cases Hommel, H., Perka, C. & Pfitzner, T. Preliminary results of a new surgical technique in total knee arthroplasty (TKA) using the native ligament tension for femoral implant positioning in varus.

Figure 4b | ADVANCE® Medial-Pivot Knee System the anterior stability of the ADVANCE® Medial-Pivot and Double-High Knees10 (Figures 4a, 4b). Femoral components with a j-curve and traditional articulation 10. Pritchett JW. Patient preferences in knee prostheses. J Bone and Joint Surgery (BR). 2004 Sept;(86-B): 979-982. 11. Eckhoff D, et. This surgical technique helps the surgeon ensure that the distal femur will be cut perpendicular to the mechanical axis and, after soft tissue balancing, will be parallel to the resected surface of the proximal tibia. Surgical Approach The surgeon can choose a midvastus approach, a . subvastus approach, or a parapatellar medial arthrotomy

We used distal release of the superficial MCL in the early period of this study and changed the surgical technique to medial epicondylar osteotomy in the latter part of the study period. Arlington, TN, USA), posterior-sacrificing in five cases (Advantim Knee), and medial-pivot knee in two cases (Advance Medial-Pivot Knees, Wright Medical. The Evolution medial pivot knee is a second-generation design that builds on the technology of the Advance knee. This article presents a retrospective review of prospectively collected data on 881 primary medial pivot knees (592 Advance knees, 289 Evolution knees) The new knee builds upon twelve years of clinical experience with the Advance medial-pivot knee. Wright's medial-pivot technology is designed to replicate the stability and function of the natural knee. The unique feature of both the medial-pivot knees is the ball-in-socket mechanism on the medial side, said David Blaha, M.D.

The unique design of the Evolution® Medial-Pivot Knee insert substitutes for both the ACL and PCL, as well as the contours of the knee to promote normal kinematics and normal feeling. See what leading knee surgeons have to say about this advanced kinematic approach and the Evolution® Medial-Pivot Knee System [4] Blaha D The Rationale for a Total Knee Implant That Confers Anteroposterior Stability Throughout Range of Motion The Journal of Arthroplasty Vol. 19 No. 4 Suppl. 1 2004. [5] Pritchett JW Patients Prefer A Bicruciate-Retaining or the Medial Pivot Total Knee Prosthesis, The Journal of Arthroplasty, 2011 Knee Replacement with advanced technology & good track record. Gold Steps make biological an In vivo comparisons of patellofemoral kinematics before and after ADVANCE Medial-Pivot total knee arthroplasty. 2012: manual technique. At mid term, a minimum of 5 years after surgery, Knee Society scores (KSSs), Knee Society Functional scores (KSFSs), range of motion (ROM), and radiographic results of 27 patients in each group were.

Decreased Survival of Medial Pivot Designs Compared with

An 11- to 15- year clinical outcome study of advance medial pivot knee arthroplasty.Bone Joint J 2016 3. Macheras GA, Galanakos SP, Lepetsos P, Anastasopoulos PP, Papadakis SA Knee (2017) A long term clinical outcome of the Medial Pivot knee arthroplasty system Clinical outcomes were The ADVANCE Medial-Pivot (MP) Knee System, which judged successful in all cases. The study design was features a ball-in-socket medial bearing with a less con- approved by the institutional review board, and all partic- forming lateral trough, is designed to create medial com- ipants provided informed consent. partment.

Evaluation of patellofemoral joint in ADVANCE ® Medial

18. Smith & Nephew Surgical Technique for Profix® TKA. 19. Stryker Surgical Technique for Scorpio® TKA. 20. MicroPort Orthopedics Surgical Technique for ADVANCE® Medial-Pivot TKA. 21. MK282-1000 22. Biomet Surgical Technique for Ascent™ TKA. 23. Johnson & Johnson, DePuy Surgical Technique for PFC® Sigma Rotating Platform TKA. 24 Fitch DA, Sedacki K, Yang Y. Mid- to long-term outcomes of a medial-pivot system for primary total knee replacement: a systematic review and meta-analysis. Bone Joint Res 2014;3:297-304. Karachalios T, Roidis N, Giotikas D, et al. A mid-term clinical outcome study of the Advance Medial Pivot knee arthroplasty. Knee 2009;16:484-8

MicroPort® Secures 15A ODEP Rating for Advance® Medial

In the normal knee, the majority of rotation occurs laterally with less motion seen medially; both condyles pivot about the intercondylar eminence as the center of rotation. This surgical technique is based on the principle that reproducing normal knee rotation is desirable when the anterior and/or posterior cruciate ligaments are sacrificed The Advance® Medial-Pivot knee system was built on the latest kinematic evidence of the natural stability and motion of the knee.[1] Its innovative design is carried on by MicroPort's latest medial-pivot knee, the Evolution® Medial-Pivot knee system, which also aims to restore function by replicating natural motion and stability, and to. The new EVOLUTION™ Medial-Pivot Knee System builds upon twelve years of clinical experience with the ADVANCE® Medial-Pivot Knee System. Wright's medial-pivot technology is designed to. Joint registry results The subset of data on the Advance Medial Pivot knee of the AOA NJRR (September 1999 to December 2010) shows that only 546 of 262 171 total TKRs (0.2%) were Advance Medial Pivot knees. The AOA NJRR data show that it has a higher rate of revision compared with the other types of TKR, 6.3% compared with 4.5% (any revision.

EMPOWR 3D Knee® DJO Globa

An 11- to 15-year clinical outcome study of the Advance Medial Pivot total knee arthroplasty: pivot knee arthroplasty. (semanticscholar.org) Primitive results after medial-pivot knee arthroplasties. (elsevier.com) The medial-pivot implant design aimed to confine anterior movement and emulate physiologic knee kinematics. (elsevier.com ACL surgery is a repair or reconstruction of the anterior cruciate ligament (ACL). The ACL is an important soft-tissue structure in the knee that connects the femur to the tibia. A partially or completely torn ACL is a common injury among athletes. Complete ACL tears are usually treated by sports medicine physicians and orthopedic surgeons with. RESULTS: Under the PCL-retaining condition, both designs showed no medial pivot but bicondylar femoral rollback more than 60 degrees of knee flexion. In the MP-design, tibiofemoral contact point (estimated contact point, ECP) of the medial compartment was located on the posterior lip of the ball-insocket structure while demonstrating greater. The ADVANCE® 913 Medial Pivot Tibial Insert and the ADVANCE® 913 Medial Pivot Tibial Base are indicated for use in knee arthroplasty for reduction or relief of pain and/or improved knee function in skeletally mature patients with the followin Look beyond the ordinary First FDA-Cleared Augmented Reality-Based Surgical Platform for Total Knee Replacement. An innovative platform that features advanced planning tools with unique soft tissue assessment, revolutionary tracking system, and augmented reality to potentially improve surgery accuracy and efficiency, with low upfront capital investment

Analysis of the Kinematics of Total Knee Prostheses With a

knee systems are designed based on this premise and drive a medial pivot. Komistek also demonstrated that patients with various knee replacement designs demonstrated a medial pivot 55% of the time.24 Given the variability in pivot in knee replacement patients, Triathlon was designed to allow the soft tissues to guide pivot the medial and lateral tibial compartment forces after mechanical alignment and ligament release to a 0° HKA angle with measured resection and gap-balancing techniques are 3 to 6 times higher than those of the native knee and kinemati-cally aligned TKA at 0°, 45°, and 90° of flexion.26,28,31,34 Kinematic alignment results in a lowe Background Medial stabilized total knee joint replacement (TKJR) construct is designed to closely replicate the kinematics of the knee. Little is known regarding comparison of clinical functional outcomes of patients utilising validated patient reported outcome measures (PROM) after medial stabilized TKJR and other construct designs.PurposeTo perform a systematic review of the available. ATTUNE® Knee System Surgical Technique DePuy Synthes Companies 7 Distal Femoral Resection If the Balanced Sizer is intended to be used, then the position of the IM hole is important as it determines the pivot point for femoral rotation. It should be selected to be 3 - 5 mm medial to the apex of the intercondylar notc

Kneeling is safe for patients implanted with medial-pivot

Purpose To evaluate minimum 5-year follow-up clinical and radiological results of total knee arthroplasty (TKA) using a posterior cruciate ligament sacrificing (PS), non-substituting Advance Medial Pivot Knee. Materials and Methods One hundred and twenty knees in 80 patients who could be followed up for more than 5 years after TKA using the PS Advance Medial Pivot Knee were evaluated. Michael J Anderson, Robert L Kruse, Chris Leslie, Louis J Levy, James W Pritchett, Jonette Hodge> ;Journal of surgical orthopaedic advances. 2010 Jan 1 Abstracts/Posters Minimum 5 Year Results of the Advance Medial Pivot Knee Pacific Surgical, Inc, Makati, Philippines. 744 likes. OUR COMPANY Pacific Surgical, formerly Pacific Spine, was founded in 2005 as a medical device and equipment distributor focused on providing..